Knowledge Base


Launch CADopia
Click on the Activate button.
Click on Activate bullet.
Click “Next” button.

To activate via “Internet”
Choose “Internet” option click “Next” button .
Fill in the information and click “Next” button .
Click on the bullet next to “Full version”.
Enter the product key (27 digit).
Click “Next” button.
At this point, your product will get activated via Internet.

To activate via “Email”
Choose “Email/Fax” option click “Next” button .
Fill in the information and click “Next” button .
Click on the bullet next to “Full version”.
Enter the product key (27 digit).
Click “Next” button.
At this point, a fax cover sheet will be generated.
This you can either email it to sales@cadopia.com or fax it to 858-777-3648.


By default, CADopia picks up the language set up of your computer, which is the language setting for the operating system on your computer. This can be changed to any other supported language (see list below) easily.

Type language on the command line.

It shows:

: language
Default: 0
Options: ? to list or
Specify language»

Typing ? displays the current list of languages supported.

0 = System
1 = German
2 = English
3 = Turkish
4 = Hungarian (not yet supported)
5 = Polish
6 = Japanese
7 = French
8 = Traditional Chinese
9 = Simplified Chinese
10 = Italian
11 = Spanish
12 = Greek (not yet supported)
13 = Korean
14 = Vietnamese (not yet supported)
15 = Catalan (not yet supported)
16 = Thai (not yet supported)
17 = Dutch (not yet supported)
18 = Russian
19 = Portuguese
20 = Czech

Type in a number shown to the left of the language to set the language. For example, type 2 to change the language to English.


In the Tools menu, click on Options entry.
The options dialog box appears.
Click on the Profles tab in the left pane.
On the right most pane, click on Reset to reset the software to its default menu and toolbar settings.
There is an alternate way to reset the settings to their default values.
Ensure that CADopia application is closed.
Go to RUN (If using Windows 8, on the Start screen, start typing run and a list of programs starting with Run will show up. Most likely, there will only be one on your computer). Click on it.

This will open up the Run dialog as shown here. You may also use any other method to bring up this dialog box that you may be familiar with.

Type %appdata% in it, this opens up a folder Appdata > Roaming .
Locate the CADopia folder in it and delete the subfolder which has a version number 11.0.466 (this number may be different based on your installed CADopia version number).
This will recreate the folder next time you start CADopia and will reset the menus and toolbars to factory settings.
If you have done any menu customizations, those customization will not appear once you reset the menus and toolbars.


On the command line, type options.
This brings up the Options dialog box. You may also bring it up from menus or toolbars.

On the left pane, Click on the System options button.

On the right pane, Expand Display by clicking on the plus sign.

Similarly expand Screen Options.

Click on Use Large Options.

Exit out of the dialog boxes and restart CADopia.


CADopia can autoload Lisp files in the following ways:

  1. start.lsp (must be located in the folder path specified for support files). Add your lisp file name with complete path details, one per line in this file.
  2. Menu Lisp (.mnl) files with the same name and location as a loaded menu XML-file(E.g. Application.xml and Application.mnl in the UI\English folder). If you have your own partial menu file, then this is the recommended solution for loading them.

The registration steps are as follows:
Launch CADopia 15
Click on the Activate button
Click on Activate bullet
Click “Next” button
Choose either “Internet” or “Email” option
Click “Next” button and fill in the information
Click “Next” button
Click on the bullet next to “Full version”
Click “Next” button
At this point, your product will get activated via Internet.
Click on “Done”.


We don’t ship a manual for CADopia 15.
Please use our online-help included in the software.
We do provide an optional courseware for purchase.


If you have activated a current license of CADopia, you can also use all previous product versions of CADopia with this activated license.

E.g. A valid CADopia 15 license will run together with CADopia 14 and CADopia 12



Note:

The activation with a product key works only with the correct CADopia product version. You can’t activate in the previous product versions with a newer product key. (e.g. CADopia 14 won’t accept a product key from CADopia 15)


Microsoft Visual Studio Tools for Applications 2012 SDK must be installed for CADopia 15 separately.
It can be downloaded from Microsoft directly under:
http://www.microsoft.com/en-us/download/details.aspx?id=38806
Please check the system requirements for VSTA 2012. It can only be used from Windows 7 SP1 and higher.
To get a properly running VSTA with editor you have to install the following programs:

  • A full-licensed CADopia 15 Professional Edition
  • Microsoft Visual Studio Tools for Applications 2012 SDK
  • Microsoft Visual Studio 2012 Professional version or higher
    • Important Note:
      Please note that the VSTA and VSTAMANAGER commands can be only used in a full-licensed version. The 30-days trial license and the demo (write-protected) mode don’t support these VSTA features.


To use a network license of CADopia you need an additional CADopia Network License Manager (NLM).
This NLM can be run as separate program or as service and it administrates the network license(s).
To get a download link to the current NLM version, please contact CADopia support@cadopia.com.
Please note that the activation of Network/Flex license cannot be done over the Internet.
You have to send us your activation data via email.


You can check the system variable OPENFORMATVERSION (values below).

Via DWGNAME you get the used file extension DXF or DWG.

Values of the opened file format are:

AutoCAD R 2.5

AutoCAD R 2.6

AutoCAD R 9.0

AutoCAD R 10

AutoCAD R 11 / 12 (R12)
AutoCAD R 13 (R13)

AutoCAD R 14 (R14)

AutoCAD R 2000 (R15)

AutoCAD R 2004 (R18)

AutoCAD R 2007 (R21)

AutoCAD R 2010 (R24)

AutoCAD R 2013 (R27)


Select ‘Options’ from the pulldown menu Tools.
Then choose in the Options dialog the icon “System Options” and expand the register “Display->Element Colors.
In the displayed list box you can select the entry “Model Background” and set your desired color.


You can change the appearance of the pointer (also named crosshairs) in the graphics area via the OPTIONS command in the page “System Options” under Graphics AREA.

Alternatively you can change the appearance of the pointer over the system variable CURSORMODE.
Enter CURSORMODE at the command line and press the key.

The possible values are

0
The pointer displays as crosshairs showing the negative parts of the X-, Y-, and Z-axis shorter. At the origin of the crosshairs, the GravityBox displays. If CURSORSIZE is 100, the crosshairs cross the entire screen.

1
The pointer displays as mouse cursor with an arrow and a box when no command is active. When a command is active and prompts to specify a point, distance, or angle, the pointer displays as crosshairs with equal lengths on the positive and negative parts of the X-, Y-, and Z-axis.

2
The pointer displays as crosshairs with equal lengths on the positive and negative parts of the X-, Y-, and Z-axis, be it that a command is active or the running command prompts to specify a point, distance, or angle.


Article 14: Error Code 5040 During the Activation Process
The error message 5040 means:
Clock setback detected – License Manager has detected that the clock has been set back. This error 5040 will only happen on expiring and trial licenses, if the computer date is set to the past during the activation process. No license key is submitted to the computer, if this error occurs.

Solution:
You should correct the time settings of his computer and then reactivate again. Another reason for this problem could be that programs with a newer date than the current are installed in the Windows system folder.

Notes:
After the reset to the current time a restart of the computer can be required. A full time-unrestricted license will always works on this computer.


• Microsoft Windows 10, 8, 2008 server (32 bit and 64 bit).
• Intel® Core™ 2 Duo or better (recommended).
• 2 GB of RAM, 4 GB or higher recommended.
• 1 GB of free hard-disk space for installation.
• High Color (16 bit) graphics card (3D graphics accelerator card recommended).
• 1024 x 768 screen resolution.
• High speed Internet access for product downloads and technical support.